Mon compte Mes selections Commander
Industrie Minière Installation portuaire Industrie du Gaz Pétrochimie Pharmacie Distillerie Stockage Chimie Agro
   

   
 
 
 
Atex System
87 Place Drouet d'Erlon
51100 REIMS FRANCE
Tel: + 33 (0)3 26 35 21 52
Fax: +33 (0)3 26 35 21 55
SARL au Capital de 83 000.00 €uros
SIRET 44188619900021
N° TVA Intra FR 58441886199

atex@atex-system.com
 
English >> Newsletter >> Archives >>
 
July 2010

20 juillet 2010


 ATEX Analogy Radio Headband Zone 0

ATEX SYSTEM presents his new system, Analogy radio headband. It is a radiocomunication equipment (transmitter / receiver) according to analogical technology.

For firemen in hostile environments. A very high level of protection against explosions by intrinsically safe.
Using
in zone 0 in gas presence, vapor, liquid (Acetylene and Hydrogen include).

Analogical radio headband associate sound pickup system with 3 modes : Vox mod, Alternate mod with osteomicrophone, laringomicrophone and De-bruitage mod.
Different speakers for sound reproduction.

Fixing kits for differents size of F1 helmets MSA.
 

Technicals data :

  • Using in Zone 0
  • Frequencies 400-440MHz or 440-470MHz
  • Decoding PL (63/250MHz)
  • Acoustic power 600mW max
  • Power supply 12VDC, 24VDC or 230VAC
  • Temperature of surface up to 135°C
  • Double lighting system

Transfer to a colleague, click on [FORWARD]

If you have any problem to view this Newsletter click on this link.

Find all informations on ATEX actually on our communications networks :


87 Place Drouet Erlon - 51100 REIMS - FRANCE
Tel : +33 (0)3 26 35 21 52 Fax : (0)3 26 35 21 55
SARL au Capital de 83.000.00 Euros
Siret : 441188619900021 - No TVA Intra FR 58411886199

For your unsubsribe on our mailinglists click on this link : [UNSUBSCRIBE]
For update your preferences click on this link :[PREFERENCES]
Conformément à la loi française Informatique et liberté n°78-17 du 6 janvier 1978. Vous disposez d'un droit d'accès et de rectification aux données vous concernant. Vous pouvez exercer ce droit en envoyant un courrier à l'adresse suivante :
Atex System 87 Place Drouet Erlon 51100 REIMS FRANCE


 
June 2010

14 juin 2010
 

Explosion-proof mobile phone XP3.10
"Extreme mobile phone"
Zone 1, zone 2 versions

XP3.10 mobile phone is setting new standard for ruggedized phones with his key features allowing to be used in any hard industrial environment.
Certified Ex ATEX Zone 1 for use in hazardous area with IP57 protection degree and MIL-810F military standard certified for marine, fog, humidity, transport shock and termal shock.

Functionality "Push-to-talk" (PTT) by GPRS network with additional subscription for illimited communications at lower costs. Better contact for your staff in hostile environment.

PUSH TO TALK Avantages :

  • Flexible and easily utilization
  • Extended network
  • Communication 1 to 1, 1 to all, 1 to group
  • "On Air" contact list available
  • Any infrastructure investment and licenses costs
  • Operators mobile GPRS networks compatibility
  • Good efficience into buildings

Unconditionally 3 year guarantee.

Hardened rubber, non-porous exoskeleton    
Operational range between -20C to +60C Keypad buttons tested to 500,000 pushes
Withstands shock-drops up to 2 meters
Scratch resistant protective screen

Waterproof and submersible for 30 min at up to 1 meter in water
 

Impervious to sand, dust, mud and industrial
micro-particles

XP3.10 Zone 1 model | XP3.10 Zone 2 model

Transfer to a colleague, click on [FORWARD]

If you have any problem to view this Newsletter click on this link.

Find all informations on ATEX actually on our communications networks :


87 Place Drouet Erlon - 51100 REIMS - FRANCE
Tel : +33 (0)3 26 35 21 52 Fax : (0)3 26 35 21 55
SARL au Capital de 83.000.00 Euros
Siret : 441188619900021 - No TVA Intra FR 58411886199

For your unsubsribe on our mailinglists click on this link : [UNSUBSCRIBE]
For update your preferences click on this link :[PREFERENCES]
Conformément à la loi française Informatique et liberté n°78-17 du 6 janvier 1978. Vous disposez d'un droit d'accès et de rectification aux données vous concernant. Vous pouvez exercer ce droit en envoyant un courrier à l'adresse suivante :
Atex System 87 Place Drouet Erlon 51100 REIMS FRANCE


 
May 2010

18 mai 2010


 CCF2DX80 ATEX Enclosure Data Radio IIB+H²

ATEX SYSTEM presents it new enclosure range IIB+H² zone 1 gas data radio transmit.
With CCF2DX80 you don't need to connect your installation by wire, delete wires.
Safety enclosure on 2.4GHz frequency for data radio transmissions.


Easily to connect on Modbus serial networks or other.
Two modes of communications (RS232, RS485).
Rapid assessment of a location's RF transmission properties, radio system FHSS : Frequency hopping spread spectrum.
Synchronization automatic.
Fully symmetric, bidirectional transceivers enable two-way communications, transmit and receive. Acknowledgements include.

Completely studished according to your specifications.

Technicals data :

  • Frequency 2.4GHz
  • Protection IIB+H²
  • Power supply +10 à +24V CC
  • Frequency hopping spread spectrum FHSS
  • Compliance EN 300 328 : V1.7.1 (2006-05)
  • Serial communication style RS232, RS485
  • Connect seammessly to Modbus serial networks

Application example :

Transfer to a colleague, click on [FORWARD]

If you have any problem to view this Newsletter click on this link.

Find all informations on ATEX actually on our communications networks :


87 Place Drouet Erlon - 51100 REIMS - FRANCE
Tel : +33 (0)3 26 35 21 52 Fax : (0)3 26 35 21 55
SARL au Capital de 83.000.00 Euros
Siret : 441188619900021 - No TVA Intra FR 58411886199

For your unsubsribe on our mailinglists click on this link : [UNSUBSCRIBE]
For update your preferences click on this link :[PREFERENCES]
Conformément à la loi française Informatique et liberté n°78-17 du 6 janvier 1978. Vous disposez d'un droit d'accès et de rectification aux données vous concernant. Vous pouvez exercer ce droit en envoyant un courrier à l'adresse suivante :
Atex System 87 Place Drouet Erlon 51100 REIMS FRANCE


 
April 2010

20 avril 2010


 CCF8AWK-4121 ATEX Wireless Enclosure IIB+H²

ATEX SYSTEM presents it new enclosure range in wireless.
This new series could be integrated in chemicals, marine, agro, oil and gas environments.

This product allow an installation in hydrogen atmosphere, it received approval compliance according to IIB+H².
This enclosure is an ideal alternative for network transmissions that are hard to wire on hazardous area.

Long-distance communication support with Wi-Fi, on several frequency 2.412 to 2.472Ghz, and 5.18 to 5.24Ghz in gas and dust zones.
Completely studished according to your specifications.

Technicals data :

  • IEEE 802.11a/b/g Compliant
  • IIB+H² Protection
  • Firewall MAC/IP/Protocol
  • SSID Protection
  • QoS (Quality of Service) Support
  • WEP, WPA, WPA2, TKIP, AES Encryption
  • Protocols DNS, HTTP, HTTPS, IP, TCP, UDP, SNMP, DHCP,..

Application example :

Transfer to a colleague, click on [FORWARD]

If you have any problem to view this Newsletter click on ce lien.

Find all informations on ATEX actually on our communications networks :


87 Place Drouet Erlon - 51100 REIMS - FRANCE
Tel : +33 (0)3 26 35 21 52 Fax : (0)3 26 35 21 55
SARL au Capital de 83.000.00 Euros
Siret : 441188619900021 - No TVA Intra FR 58411886199

For your unsubsribe on our mailinglists click on this link : [UNSUBSCRIBE]
For update your preferences click on this link :[PREFERENCES]
Conformément à la loi française Informatique et liberté n°78-17 du 6 janvier 1978. Vous disposez d'un droit d'accès et de rectification aux données vous concernant. Vous pouvez exercer ce droit en envoyant un courrier à l'adresse suivante :
Atex System 87 Place Drouet Erlon 51100 REIMS FRANCE



Atex System sur Blogger Atex System sur Facebook Atex System sur Twitter Follow-up of the site's activity RSS 2.0 | Private area


1 | 2 | 3 | 4

Contact Us
-
Actually Products
-
Risk Explosions
-
Events
-
Economy

Atex System
-
Presentation
-
Quality
-
Company profile

Legislative texts
-
Atex poster
-
Atex guidelines
-
Directive 2002/96/CE
-
New references of harmonised standards
-
ATEX product marking.

The latest ATEX, oil and gaz news

Atex related blogs

Movies Atex risks
-
Static electricity in a gas station
-
Ignition with a cell phone
-
LPG leak
-
Dust explosion

Links

Newsletter
-
Registration
-
Archives

 
 
Art-Touch